Home ProductsMarine Diesel Generator

6 Cylinder 200 KW Marine Diesel Generator For Emergency CCS BV Certification

6 Cylinder 200 KW Marine Diesel Generator For Emergency CCS BV Certification

    • 6 Cylinder 200 KW Marine Diesel Generator For Emergency CCS BV Certification
    • 6 Cylinder 200 KW Marine Diesel Generator For Emergency CCS BV Certification
    • 6 Cylinder 200 KW Marine Diesel Generator For Emergency CCS BV Certification
    • 6 Cylinder 200 KW Marine Diesel Generator For Emergency CCS BV Certification
  • 6 Cylinder 200 KW Marine Diesel Generator For Emergency CCS BV Certification

    Product Details:

    Place of Origin: Weifang
    Brand Name: weichai power
    Certification: CCS/BV/ISO/CE
    Model Number: CCFJ200Y-W*

    Payment & Shipping Terms:

    Minimum Order Quantity: 1set
    Price: Negotiation
    Packaging Details: Plastic Foam or Plywood Case
    Delivery Time: 35 working days
    Payment Terms: T/T, L/C, Western Union
    Supply Ability: 30 sets per month
    Contact Now
    Detailed Product Description
    Product Name: Diesel Generator Engine Color: Marine Blue
    Purpose: Marine Emergency Generating On Deck Principle: Electromagnetic Induction Principle
    Dimension: 2898*918*1522mm Weight: 2435kg
    Displacement: 11.596L Fuel Consumption: 48.9L/h

              6 cylinder Weichai 200KW marine generator with CCS BV certificate for boats

     


    Technics:

     

    Specification of genset
    Gensets model CCFJ200Y-W*
    Rated power 200KW
    Rated voltage 400/230V
    Rated current 271A
    Rated frequency(HZ) 50
    Rated speed 1500rpm
    Power factor 0.8(lagging)
    Dimensions(mm) (L×W×H) 2687*918*1799
    Genset weight(kg) 2180
    Specification of diesel engine
    Engine brand weichai steyr
    Engine model WP10CD264E200
    Number of Cylinders 6
    Cylinder arrangement Vertical in-line
    Cycle Four stroke
    Aspiration Turbocharged
    Bore×Stroke (mm×mm) 126x 155
    Displacement (Liter) 11.596L
    Rated power 240KW
    Rated speed 1500rpm
    Starting Method DC24V electrical starting and air starting
    Speed Governor Electronic
    Cooling System Fan closed water-cooling
    Fuel Consumption 197g/kw.h
    Specification of alternator
    Alternator brand Sanbo,Marathon,Siemens or Stamford
    Rated voltage 400/230V
    Number of Phase 3
    Connecting Type 3 Phase and 4 Wires
    Number of Bearing 1
    Protection Grade IP23
    Exciter Type Brushless ,Self-exciting, AVR automatic voltage regulating,100% Copper winding wire
    Insulation Class H

     6 Cylinder 200 KW Marine Diesel Generator For Emergency CCS BV Certification

    Model list of Steyr series marine emergency generating set
     

    Genset model Rated power(KW) Rated voltage(V) Rated current(A) Rated fuel consump(kg/h)   Weichai Steyr  

     

    Alternator brand

    Engine model Rated power(kw) Cooling method
     CCFJ150Y-W*   150  400  271  36.7  WP10CD100E200

     

    182

     Closed cooling  Lanzhou/amarathon/siemens/stamford
     CCFJ180Y-W*   180  400  325  44.1 WP10CD238E200   216  Closed cooling  Lanzhou/amarathon/siemens/stamford
     CCFJ200Y-W*   200  400   361  48.9 WP10CD264E200   240  Closed cooling Lanzhou/amarathon/siemens/stamford 
     CCFJ220Y-W*   220  400   397  50.6 WP12CD317E200   288  Closed cooling  Lanzhou/amarathon/siemens/stamford
     CCFJ250Y-W*   250  400   451  61.9 WP12CD317E200   288  Closed cooling  Lanzhou/amarathon/siemens/stamford
     CCFJ300Y-W*   300  400   541  74.3 WP13CD385E200   350  Closed cooling  Lanzhou/amarathon/siemens/stamford

    REMARK:The other speciall requirements you need can be satisfied,please email me in details.

    Steyr series marine emergency

    The power range of Weichai Steyr series marine emergency gensets is 150-300KW.The gensets is used the engine reserached,developed & manufatured by Weichai Group independently,and the optional brand name generator like Sanbo,Marathon,Siemens or Stamford generator.All gensets manaufacturing @ testing is carried out as GB/T13032-2010 Marine diesel gensets general technique requirements.

    Product characteristics

     

    1. Marine emergency instrument boxes show reliable performance. The function of self-starting can be realized. In automatic state, once gen-sets detect the fault of main power, they automatically conduct the following actions: starting, raising speed, sending switching signals, and the time from the gen-sets detecting the fault to sending switching signal is not more than 45 second. When gen-sets detect that the main power returns to normal, they automatically conduct the following actions: sending tripping signals, decelerating, cold machine running for 120 seconds and then halt. At the same time some parameters of speed, oil pressure and water temperature can be displayed and gen-sets can achieve alarm protection.

     

    2. Emergency gen-sets use bi-motors start, starting fast and reliably, electric starting motor and gas starting motor both an the standard configuration, spring starting motor as the optional configuration.

    6 Cylinder 200 KW Marine Diesel Generator For Emergency CCS BV Certification

    Contact Details
    Weichai Power Generation Taizhou Co.,Ltd

    Contact Person: Mr.james

    Tel: +8615062994302

    Send your inquiry directly to us (0 / 3000)